Emergency Service 24/7715.423.6310
This rate will be applied to customers for all types of service if their monthly Maximum Measured Demand is in excess of 200 kilowatts (kW) per month for three or more months in a consecutive 12-month period.
A customer billed on this rate shall continue to be billed on this rate until their monthly Maximum Measured Demand is less than 200 kW per month for 12 consecutive months. This utility shall annually offer a customer billed on this rate the option to continue to be billed on this rate for another 12 months if their monthly Maximum Measured Demand is less than 200 kW per month. However, this option shall be offered with the provision that the customer waives all rights to billing adjustments arising form a claim that the bill for service would be less on another rate schedule that under this rate schedule.
$75.00 per month
$1.25 per kW of the highest monthly Maximum Measured Demand occurring in the current month or preceding 12-month period.
$6.00 per kW of billed demand
$0.0696 per kWh
$10.00 Monthly Charge
Charge per all kWh, varies monthly. (See schedule PCAC)
The minimum monthly bill shall be equal to the customer charge, plus $1.50 per kW of the highest monthly Maximum Measured Demand occurring in the current month or preceding 11-month period.
A charge of 3% but not less than 30 cents will be added to bills not paid within 20 days form date of issuance. A late payment charge shall be applied only once to any given amount outstanding. This charge is applicable to all customers.
Customers metered on the primary side of the transformer shall be given a 2.00 percent discount on the monthly energy charge, customer demand charge and demand charge. The PCAC and the monthly customer charge will not be eligible for the primary metering discount.
The maximum measured demand in any month shall be that demand in kilowatts necessary to supply the average kilowatts in 15 consecutive minutes of greatest consumption of electricity during each month. Such maximum measured demand shall be determined from readings of permanently installed meters or, at the option of the utility, by any standard methods or meters. Said demand meter shall be reset to zero when the meter is read each month.
When the average monthly Power Factor is equal to or greater than 90.00 percent, the Maximum Measured Demand shall be the Billed Demand.
When the Average Monthly Power Factor is less than 90.00 percent, the Maximum Measured Demand shall be adjusted to obtain the Billed Demand. Billed Demand shall be determined each month by the following formula:
The Average Power Factor is obtained by the following formula, where
Any reactive component meter used shall be equipped with ratchets to prevent registration of leading power factor.
A complete set of Authorized Rates and Rules is available at the Utility Office.